Multiple Gas Analyzer #2 GC Systems
6-7


8610-0270
  • Separates a wide variety of peaks in a single injection, including water
  • Very tolerant of user adjustments and timing variations
  • Simpler than other multiple gas capable system

The basic model includes:

  • TCD Detector
  • MoleSieve 13X & Hayesep-D Columns
  • Temperature Programmable Column Oven
  • 10-port Gas Sampling Valve and Dual Loops
  • 1 channel PeakSimple Data System
  • On-Column Injector
    ...on the compact 8610C chassis

The Multiple Gas Analyzer #2 GC system (MG#2) is pre-plumbed and ready to resolve H2, O2, N2, methane, CO, ethane, CO2, ethylene, NOx, water, alcohols, propane, butanes, pentanes, and C6+. The MG#2 is similar to the MG#1, except that the MG#2 can measure water and alcohol in addition to the multiple gas compounds.

To separate such a wide variety of peaks without co-elution, the MG#2 turns on the carrier gas flow to each column at different times during the run. This allows the Molecular Sieve column to complete the separation of H2, O2, N2, CH4 and CO, at which point the MoleSieve carrier flow is turned off and the Hayesep-D carrier flow is turned on. The Hayesep-D column then separates all compounds in the C1-C6 range. A capillary column in parallel with the Hayesep-D can also be useful in separating the hydrocarbons out through C20. Detectors can be TCD, HID, FID, or any combination, depending on your application needs.

This chromatogram shows the separation of a 1% Gas Standard sample on a MG#2 eqipped with a TCD detector. The first five peaks came off the MoleSieve column, and the following three peaks came off the Hayesep-D column. Note that the methane elutes twice, once from each column.
These two chromatograms show the separation of a 1000ppm C1-C6 standard plus room air on a MG#2 GC equipped with TCD (bottom chromatogram) and FID (top chromatogram) detectors.

8610-0271 customized with an HID detector and a 30-meter capillary column

This customized MG#2 is equipped with:
  • TCD Detector
  • HID Detector
  • FID-Methanizer
  • 30-meter Capillary Column
  • MoleSieve 13X & Haysep-D Columns
  • Temperature Programmable Column Oven
  • 10-port Gas Sampling Valve and Dual Loops
  • 4 channel PeakSimple Data System
  • On-Column Injector

8610-0270
Multiple Gas Analyzer #2 with TCD detector and 1 channel PeakSimple data system
8610-0271
Multiple Gas Analyzer #2 with TCD, Methanizer, FID, built-in "whisper quiet" air compressor, and 4 channel PeakSimple data system
8610-0272
Multiple Gas Analyzer #2 with TCD and HID detectors, and 4 channel PeakSimple data system